CONTENTS
1.Scope
2.Qualification of NDE Personnel.
3.Procedure
4.Magnetizing Equipment and Material
5.Surface Preparation
6.Examination
7.Evaluation
8.Demagnetization
9.Reexamination for repaired Area and Nonconformity Control
10.Post Cleaning
11.Report
SUSPENSION CONCENTRATION CALIBRATION RECORD
MAGNETIC PARTICLE EXAMINATION INSTRUCTION
MAGNETIC PARTICLE EXAMINATION REPORT
1.Scope
1.1.This procedure is applied to detect cracks and other discontinuities on or near the surface of ferromagnetic materials, using wet magnetic particle and AC or DC yoke technique with continuous magnetization method
1.2.This procedure is applied to welds and materials of ASME Code pressure vessels fabricated according to ASME Code Section Ⅷ Division 1.
2.Qualification of NDE Personnel
All personnel performing magnetic particle examination shall be qualified and certified in accordance with the requirements of HT’s Written Practice for NDE Personnel Training, Examination, Qualification and Certification based on the requirements of“SNT-TC-1A”(Current Code accepted edition)
3.Procedure
This procedure shall be supplemented by MAGNETIC PARTICLE EXAMINATION INSTRUCTION which shall be issued to every product to be examined and in which more detail parameters are specified. The Instruction shall be prepared by level Ⅱ,approved by level Ⅲ NDE examiner,
4.Magnetizing Equipment and Materials
4.1 Magnetizing equipment
4.1.1The magnetizing equipment shown in Table 1 shall be used.
Table 1
Manufacturer
Model
Factory No.
Type
Technique
SHE YANG
CYE-1
030
AC or DC
Yoke Technique 4.1.2.Calibration of Equipment
The magnetizing equipment shall be calibrated at least once a year, or whenever the equipment has been damaged. If the equipment has not been in use for a year or more, calibration shall be done prior to first use. The magnetizing equipment shall be calibrated in accordance with the requirements of MAGNETIC PARTICLE