Sea trial report
Sheet3
Sheet2
Sea trial
Elec cable ( D/K fwd(p) end ) not connected.电缆未连接(地管隧艏部左舷)
D/K bilge alarm sensor not tightened.( near BW 137) 地管隧舱底水报警传感器没有紧固(BWV 137附近)
HFO hose davit to be provided with additional lashing pad eye.燃油软管吊要增加
No frame net vent in middle store 中部储藏室风道少网
Stair way in living quarter not vetilated properly.
No.1 DBT? remote sounding sensor coupling leaked.No.1 DBT?液位遥测传感器联轴节处有泄露
No tight u-bolt in duck keel (s) near BWV 106 地管隧右舷离阀BWV106处一U型卡环未把紧
Missing 1 nut in duck keel (p) near BWV117 地管隧左舷离阀BWV137处少一螺目
Mooring winch hyd. Pipe in S/G rm be leaking , topside of FW (S) tank 舵机室内,淡水舱(右)顶部绞缆机液压管漏油
Funnel dampers were not fitted properly aginst Heavy rain from aftward.( Unproper angle length of flap damper
Modify air service pipe for safety 空气系统管要修改:
* poop deck (ps ) *尾楼甲板(左舷/右舷)
* near LS HFO service tank. *靠近低硫燃油日用舱
* near C/Hold washing pump. *靠近货舱扫舱泵
Fan damper actuator for purifier room not fixed Firmly.
分油机室风机防火风闸执行器要紧固
Touched between hyd pipe and handrail for L/B Davit during lowering.
救生艇吊在下降时液压管与扶手相碰
All the railing near stern tube gravity tank to be secured. One additional railing to be provided
Complete air trunking on top of main air compressor on the E/R lower platform aft side is moving , same to be adequately strengthened.
Provision gantry crane to be provided with end stoppers on both port and starboard side.
Not installed properly for remote sounding pipe Sensor in No.3 TST(S)
No.3 TST(S) 液位遥测传感器要紧固
Ref.pipe ragging of provision plant was not fitted Properly.
For emergency Generator eng room.应急发电机室:
* Door hinge of No.2 eng room vent fam for Starter panel is detached.
2号机舱风机启动控制板门需调节
* Exhaust pipe insulation not fitted properly. 排烟管绝缘未能很好的固定
* drain pipe for cooling fan was not installed .冷却风扇泄放管未装
FW valve FW118 inlet to A/E jacket water heater is vibrating additional support to be provided发电机缸套水加热器进口阀FW118处,震动厉害,要加支架
Pipe duct to be fitted with securing arrangement for t
您可能关注的文档
最近下载
- 安全生产推进小组成立文件.docx VIP
- (精)防人因培训.ppt
- 4.3 信息系统在社会应用中的优势及局限性 课件-2022-2023学年粤教版(2019)高中信息技术必修2.pptx VIP
- 2021医院必威体育官网网址培训课件.pptx
- 必威体育精装版GBT20647.9物业服务管理体系一整套文件(手册+程序文件+管理制度+表单).pdf
- 9.2 提高防护能力 2024-2025学年七年级道德与法治上册高效备课精品课件(统编版2024).pptx VIP
- xx小学学平险问题专项整治实施方案.doc
- 可靠性试验培训.ppt
- 2.3 涡流、电磁阻尼和电磁驱动 教学设计 -2024-2025学年高二下学期物理人教版(2019)选择性必修第二册.docx
- 国家建筑标准设计图集15J207-1 单层防水卷材屋面建筑构造(一)金属屋面.pdf
文档评论(0)