Gamma射线消毒环氧乙烷消毒前后的PS的性能.pdfVIP

Gamma射线消毒环氧乙烷消毒前后的PS的性能.pdf

  1. 1、本文档共4页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Gamma射线消毒环氧乙烷消毒前后的PS的性能,环氧乙烷消毒设备,环氧乙烷消毒,环氧乙烷消毒柜,环氧乙烷熏蒸消毒,紫外线和环氧乙烷消毒,环氧乙烷消毒原理,上海环氧乙烷消毒地方,苏州环氧乙烷消毒,环氧乙烷消毒剂

Technical Bulletin NOVA Chemicals Effects of Gamma Irradiation and Ethylene Oxide Sterilization on the Appearance and Physical Properties Of Crystal and Impact Polystyrene TECHNICAL DATA The sterilization of plastics has become increasingly important as the use of plastics in medical applications and aseptic packaging has become more frequent. Sterilization by high-energy radiation, such as gamma or electron beam irradiation, is popular, since it avoids the use of chemicals that may leave residues in the plastics. Alternatively, a simpler process involves exposure of the specimens to ethylene oxide gas for a pre-determined length of time. The effects of both methods were evaluated in this long-term study, and dosage levels were equivalent to and/or exceeded the normally required amounts. Molded 1/8 tensile bars, Izod bars, and 2.5” diameter disks of these two materials were exposed to both methods of sterilization to evaluate the effect on physical properties. Properties were tested before and after exposure to measure the initial effects, and then samples were retained and tested over time to evaluate long-term effects. The complete results of the evaluations of the exposed materials are presented in Tables 3 and 4. The following conclusions can be made based on these results and tables of percent retained properties after 2 years are also included. 1. Physical Properties and Yellowness Indices of High Heat Crystal Polystyrene The melt flow indices of the High Heat Crystal Polystyrene samples were slightly affected by exposure to both types of sterilization methods. The tensile strength and % tensile elongation properties were relatively unaffected by exposure to 25 kGray (2.5 Megarads, single dose) and 50 kGray (5.0 Megarads, double dose) of gamma irradiation. Ethylene oxide sterilization (single dose) had a more noticeable effect on tensile strength and elongation. The yellown

文档评论(0)

xingkongwd + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档