No More Electrical strongInfrastructurestrong Towards Fuel Cell Powered.pdfVIP

No More Electrical strongInfrastructurestrong Towards Fuel Cell Powered.pdf

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
No More Electrical Infrastructure: Towards Fuel Cell Powered Data Centers Ana Carolina Riekstin Sean James Aman Kansal University of Sao Paulo Microsoft Research Microsoft Research carolina.riekstin@usp.br seanja@ kansal@ Jie Liu Eric Peterson Microsoft Research Microsoft Research liuj@ eric.peterson@ ABSTRACT The first reason to consider FCs as data center power We consider the use of fuel cells for powering data cen- systems is reliability. The gas grid infrastructure is mainly ters, based on benefits in reliability, capital and opera- buried and not subjected to severe weather. Gas pumps tional costs, and reduced environmental emissions. Us- themselves are typically power by a portion of the gas ing fuel cells effectively in data centers introduces sev- flowing through the stations. Gas grid reliability is known eral challenges and we highlight key research questions to be high, and the delivery contracts exhibit reliabil- for designing a fuel cell based data center power distri- ity greater than 99.999% [12], much higher than the bution system. We analyze a specific configuration in 99.9% or less for the electric grid. As a result, FCs the design space to quantify the cost benefits for a large can eliminate diesel generators and batteries used for scale data center, for the most mature and commonly power backup. Local gas tanks

文档评论(0)

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档