Operating Procedure for Temperature Uniformity Survey of 50t Aging Furnace.doc

Operating Procedure for Temperature Uniformity Survey of 50t Aging Furnace.doc

  1. 1、本文档共19页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Operating Procedure for Temperature Uniformity Survey of 50t Aging Furnace

50吨时效炉炉温均匀性测试操作规程 Operating Procedure for Temperature Uniformity Survey of 50t Aging Furnace Q/SWA JH02A.15-2011 1 范围: 1. Scope 1.1 本规程规定了50吨时效炉的炉温均匀性测试操作要求。 1.1 This procedure stipulates requirements for the temperature uniformity survey of 50t ageing furnace. 1.2 本规定适应于50吨时效炉的炉温均匀性测试工作。 1.2 This procedure applies to operations of the temperature uniformity survey of 50t aging furnace. 1.3 本规程根据AMS 2750D制定。 1.3 The procedure is established according to AMS 2750D. 2 要求 2. Requirements 2.1 热处理设备及要求 2.1 Heat Treatment Equipment and Requirements 2.1.1 设备代码:02 Sxl 50 2.1.1 Equipment Code: 02 Sxl 50 2.1.2 50吨时效炉符合AMS2750D中规定的Ⅱ级炉及D类仪器 2.1.2 50t aging furnace conforms with class 2 furnace and class D instruments in AMS2750D. 2.1.3 炉膛尺寸:17000×4500×2000mm(长×宽×高) 2.3.1 The chamber size of the furnace: 17000×4500×2000mm(L×W×H) 2.1.4 有效工作区尺寸:16000×4000×1600mm(长×宽×高) 2.1.4 The ffective working zonr size: 16000×4000×1600mm(L×W×H) 2.1.5 有效工作区分区:六区(1,2,3,4,5,6区) 2.1.5 Effective working zones of the furnace: 6 zones (zone No. 1,2,3,4 ,5 and 6) 2.1.6 工作温度:110-220℃ 2.1.6 Working temperature: 110-220℃. 2.1.7 炉温均匀性要求:±5℃(±10℉) 2.1.7 Requirement for temperature uniformity in the furnace: ±5℃(±10) 2.2 Frequency of the temperature uniformity survey of the furnace 2.2.1 定期测试: 2.2.12.2.1.1 炉温均匀性定期测试周期为一月,测试时间间隔到期后允许延长3天。emperature uniformity test is periodically conducted for one (1) month during normal production with three (3) days extending after expiration of the interval. 2.2.1.2 如果AMS2750D要求连续8次测试,则测试可。2.2.1.2 If the results of contuuous 8 times of survey are acceptable according to the relevant requirements of AMS 2750D, the test interval can be extended for two months. 2.2.2 初次测试:2.2.2.1 参考AMS2750D 3.5.3和3.5.4条,确认炉子调整、改型或维修炉子温度均匀特性了改变时,必须进行初次测。2.2.2.2 如果某次测试结果不合格,则下次执行初次测测试周期复到每月一次直至达到测试周期延长条件时止。2.3.1 Test mode: empty furnamce, support-type, volume measuring method 2.3.2 测试传感器准备: 2.3.2 Preparation of test sensor 2.3.2.1 测试传感器:符合表1要求 2.3.

文档评论(0)

bigone123 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档