Heat transfer
There is a tube and shell heat exchanger,and its outside area is A=40m2 . The tube is (25(2.5mm made up of steel. saturation steam which pressure is 2atm(a) in shell side is used to heat 2.5(104kg/h oil from 40(C to 80(C, and the individual coefficient of steam condensation is 1.2(104w/(m2K).Oil flows in tube side in turbulent flow, and its mean specific capacity is
1 The amount of oil treated increases one time, m(=2m, calculate the outlet temperature of the oil? If the outlet temperature of oil remains 80(C,whether heat exchanger is suitable?
2 Measures to be taken if the heat exchanger is unsuitable ?
3 Calculate A if another heat exchanger is added in series / parallel connection?What problems should be taken into consideration?
4 Whether the outlet temperature of oil remains 80(C if steam pressure is increased to 3atm?
5 Flowrate of the oil is fixed, and the oil viscosity is twice that of before. Other physical properties are fixed. please calculate outlet temperature of the oil .
6 After prolonged usage,there is thermal resistance of scale deposited on the outside surface of tubes, and the thickness is 1mm, k=0.2w/(mK) ,please calculate the outlet temperature of oil .
7 The atmosphere temperature is 10(C,and the individual coefficient by convection from surface to air is calculated according to the equ. :
The shell of the exchanger is 400 ( 8mm,and the temperature of the shell is 30(C after preservation. The thermal conductivity of the logging material is 0.058w/(mK)
Calculate the thickness of the logging material, and the steam saved per month.
1.The amount of oil treated increases one time, m(=2m ,calculate the outlet temperature of oil? If the outlet temperature of oil remains 80(C,whether heat exchanger is suitable?
To check whether heat exchanger is suitable
to maintain outlet temperature,check A
1)U
Thermal resistance mainly in tube side
(2) whether heat exchanger is suitable?
m(=2m ,
unsuitable
您可能关注的文档
最近下载
- 一种检测磷酸铁锂粉末中磁性金属异物及磷化铁含量的方法.pdf VIP
- 2023年华为公司招聘职位要求.pdf
- 三年级心理健康第1-16课全册教案.pdf
- 2021面瘫的针灸治疗测试题【附答案】.doc
- IATF16949第五版DFMEA管理程序+潜在失效模式及后果分析程序.doc
- 智慧城市大数据平台设计方案.pdf VIP
- 匹兹堡睡眠质量指数(PSQI)表格版-打印保健养生.docx
- 林木林地权属争议处理申请书(样本).pptx
- 手机销售网站的设计与实现.doc VIP
- 河南省图集 12YN6、12YN7、12YN9 热力工程、民用建筑空调与供暖冷热计量设计与安装 DBJT19-07-2012.docx
文档评论(0)