《QJgasrelaymanuals
INSTRUCTION OF
QJ SERLES GAS RELAY
APPROVAL TO ISO9001 QUALITY SYSTEM CERTIFICATION
SHENYANG SIXING RELAY MANUFACTURELTD CHINA
Application
The Gas relay series QJ is protective device for oil immered transformer. If a fault causes gas to be generated in the transformer or a heavy surge of insulating oil the Gas relay shall be in operation, the alarm signal is initeated and/or the transformer is tripped automatically.
Principle of design
When the transformer is operating normally, the Gas relay is completely filled with insulating oil .If a fault causes gas to be generated in the transformer, the bubble will filter along towards the conservator and accumulated at the highest point in the Gas relay. As the amount of gas coquette increases and the oil level in relay fall as a result, the cup also falls and eventually reaches point where it actuates the magnetic switch with the permanent magnet and so initiated the alarm signal. If the oil loses, the alarm signal is also initiated A violent generation of gas accompanied by a heavy surge of insulating oil results in operation of baffle plate. the magnetic is actuated by the permantmagnet on the baffle plate so it trips the transformer.
3、Technical data
(1) Working temperature: -30°C~95°C
(2) Switch Capacity: AC 220V 0.3A COSφ≤0.6
DC 220V 0.3A S≤5×10-3S
(3) Operation Character: Table Ⅰ
Type QJ-80 QJ-50 QJ-25 Range of flow(m/s) 0.7~1.5 0.6~1.2 1.0 Gas accumulation (ml) 250~300 <250 (4) Sealing character: filling transformer oil into the relay, Pressurizing normal temperature 200kPa,Continued 20 min and without any leakage.
(5) Insulation Character Table Ⅱ
Test item Voltage between contacts Voltage between terminal and earth Voltage between signal and trippingterminal Bring to bear on industry voltaye 2000v /1 min 2000v /1 min 2000v /1 min (6) Antivibration capacity
When acceleration is 4g at
您可能关注的文档
最近下载
- 【行业标准】NBT 47041-2014 塔式容器.pdf
- 内蒙古版三年级综合实践活动指导第3单元主题活动四《多彩的泡泡》.ppt
- 老年痴呆护理查房ppt.pptx
- 感冒药的正确使用.pdf
- 调色师:达芬奇视频剪辑调色从入门到精通第11章 综合案例:制作《云彩之美》效果.pptx VIP
- 调色师:达芬奇视频剪辑调色从入门到精通第10章 综合案例:制作《银河星空》延时效果.pptx VIP
- 2020年上海黄浦区高三二模语文试卷(答案、解析版).pdf VIP
- 调色师:达芬奇视频剪辑调色从入门到精通第9章 抖音热门调色.pptx VIP
- (正式版)G-B 4839-2009 农药中文通用名称.docx VIP
- 语文一年级上册核心素养教案全册.pdf VIP
文档评论(0)