不同加载方式SIP墙体的抗剪性能.doc

不同加载方式SIP墙体的抗剪性能   摘要:以3种不同的单向加载方式对以木质OSB覆面的SIP墙体进行侧向加载实验,对比分析3种加载方式下SIP墙体的破坏形式及这3种加载方式对墙体抗剪性能参数的影响,结果表明:3种加载方式得到的墙体的抗剪性能指标有所差异,其中,采用ISO22452加载协议,即对墙体施加持续增加载荷的加载方式所得到的极限承载力最大、极限位移和延性系数居中,分别为46.06 kN、71.83 mm、3.31;采用ASTM E72-05加载时极限承载力居中、极限位移及延性系数最大,分别为:40.66 kN、76.97 mm、4.07。采用ASTM E564-06加载,即对墙体施加阶段载荷并使阶段目标载荷持续作用一段时间的方式,所得到的极限承载力、极限位移及延性系数最小,分别为37.73 kN、54.92 mm、2.91;3种加载方式对墙体破坏形式的影响不大。   关键词:SIP墙体;静力单向加载协议;破坏形式;抗剪性能   中图分类号:TU531.11   文献标志码:A 文章编号:1674-4764(2016)03-0041-07   Abstract:Three different static loading protocols were used in the lateral loading experiment on SIP wall covering with oriented strand board (OSB), and failure forms and shear performance of the SIP wall were recorded and analysed treated by three loading protocols: ISO 22452, ASTM E72-05 and ASTM E564-06. The results showed that shear performances of the SIP walls under the three loading protocols were different, ultimate bearing capacity and ultimate displacement were the largest one, and the ductility factor was the middle one which loaded by ISO 22452, the value were 46.06kN, 71.83mm, 3.31 respectively; while ultimate bearing capacity was the middle one, ultimate displacement and ductility factor were the largest one which loaded by ASTM E72-05, the datas were 40.66kN, 76.97 mm, 4.07 respectively; ultimate bearing capacity 37.73 kN, ultimate displacement 54.92 mm and ductility factor 2.91 were the smallest treated by ASTM E564-06 among the three loading protocols. Failure forms of the walls under the three loading protocols were similar, there were little influence on failure forms caused by the three loading protocols used in this research.   Keywords:SIP wall; static loading protocol; failure forms; shear performance   结构保温板,也称结构隔热板 (SIP,structural insulated panels),是以硬质发泡材料或其他保温材料为夹心层,外贴压型钢板、木板、水泥加压板等薄板的三明治型的复合板材,常见的芯材种类有:EPS、XPS、PU以及无机类保温材料等,贴面板有:压型钢板、欧松板、桔梗板等木质板材、水泥加压板、石膏板等无机板材。该结构类型的复合板材具有良好的保温隔热性能、抗震性能及轻质高强的特点[1-2], 提高了木材利用率,创造出比传统木结构形式更加先进的SIP 住宅系统(structural insulated

文档评论(0)

yingzhiguo + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:5243141323000000

1亿VIP精品文档

相关文档