113200493ADE7754_Features_March2003New.pdf

  1. 1、本文档共26页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
113200493ADE7754_Features_March2003New

The World Leader in High Performance Signal Processing Solutions Multi-functional Polyphase Energy Metering IC with Serial Port Interface ADE7754 Energy Measurement Group Precision Converters (PRC) Division 2 a ADE7754: A programmable solution for Polyphase Energy measurementTransducers 3 a ADE7754: Technology at a glance 4 a ADE7754: Overview of Functionalities ? Surpasses IEC1036 requirement. Less than 0.1% error over wide dynamic range ? Supplies the following information: Active energy Sign of Reactive energy Apparent energy Simultaneous RMS calculation on the six analog inputs Peak Voltage and Current detection SAG Line Voltage detection Line Period Temperature ? Digital calibration 5 a ADE7754: Characteristics ? 24-pin SOIC package ? 5V Power Supply ? [-40 C; +85 C] Temperature Operating range ? 500mV maximum analog input range with PGA of 1, 2 or 4 on all channels ? External Clock frequency = 10MHz 6 a ADE7754: Block Diagram ? Analog Front end ? Current sensor connection ? Digital solution ? Active Energy ? Calibration Mode ? RMS measurements ? Apparent Energy ? Reactive Energy ? Power Line Quality ? Temperature sensor 7 a ADE7754: A validated Analog front end ? Analog Front end ? Current sensor connection ? Digital solution ? RMS measurements ? Active Energy ? Apparent Energy ? Calibration Mode ? Reactive Energy ? Power Line Quality ? Temperature sensor ? 16-bit accuracy from 2nd order ΣΔ ADCs ? Linearity error 0.1% over wide dynamic range (int. reference) ? Measurement Bandwidth 14 kHz 8 a ADE7754: Easy use of Current sensors ? Input Gain up to 4 ? Phase compensation for CT connection ~ +/-0.5°max in 0.02°increment @ 50Hz ? Analog Front end ? Current sensor connection ? Digital solution ? RMS measurements ? Active Energy ? Apparent Energy ? Calibration Mode ? Reactive Energy ? Power Line Quality ? Temperature sensor 9 a ADE7754: A Digital solution ? Configuration done by writing ADE7754 registers at power up ? Only one point calibration to reac

文档评论(0)

l215322 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档