无梁空心楼盖结构设计浅析(国外英文资料).doc

无梁空心楼盖结构设计浅析(国外英文资料).doc

  1. 1、本文档共4页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
无梁空心楼盖结构设计浅析(国外英文资料)

无梁空心楼盖结构设计浅析(国外英文资料) When the multi-layer span is not too large, it is advisable to reduce the reinforcement, and when the high level or the span is large, consider the reduction of the weight. When using the rectangular module, the rib width should not be less than 100mm, when the rectangular cavity is larger, consider 150mm or 200mm. Built-in mold hollow slab bottom in pipeline flange height should consider board games, factors, such as hanging bolts in reference [1] section 6.1 structure requirements should not be less than 50 mm, the author suggest not less than 55 mm, span or when load is bigger, can consider to 60 mm or larger. (2) dark beams should be set in earthquake resistance, and the width of the dark beam shall not be greater than the width of the column and the 1.5 * hs per side. The mast cap must be set when the area is 8 degrees. (3) hollow slab thickness are generally not less than 250 mm, so can be compressed in the top plate across the set structure reinforcement, suggest not less than the calculated by equivalent thickness reinforcement ratio of 0.15%. The spacing of the bar is appropriate to the module of the intercostal space. (4) to the requirement of plates with longitudinal ribs, appropriate to add additional reinforcement in the form of long muscle, additional reinforcement length preferable half span calculation, but in the column upper belt, additional muscle stretch out the length of the column cap side should not be less than 1000 mm. When the reinforcement mode is not reinforced by the addition of the reinforced reinforcement, the reference [1] 6.3.3 is carried out. (5) the hollow panel should be properly configured in the following situations: 1) when the plate is thicker than 350mm 2) when the load is heavier, such as covering dirt or walking a fire truck 3), the ribs are small, the installation of the fixed scheme is not secure, and the lateral shift may occur under the thrust of the concrete 4), the end rib of the cylinder core is

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档