DLT 606.3-1996火力发电厂热平衡导则要点
火力发电厂热平衡导则
DL/T606.3- 1996
DL/`C606.3- 1996
目 次
前 言 .·701
1 范围 ·······························································································…… 702
2 引用标准 ··············,·········,·······························································…… 702
3 总则 ·······················································································,·······…… 702
4 名词解释、符号、代号 ·······································································…·…702
5 热平衡测试内容及方法 ·····································································…… 703
6 热平衡测试的准备工作 ····································································…·…703
7热平衡测试数据的整理 ······························································…·…703
8 热平衡结果分析 ·······································································.··.······…… 705
9热平衡总结报告 ··································································,···········…·…,‘705
附录A(标准的附录)············································································‘·……7日
附录B(标准的附录)再热蒸汽流量、连续排污扩容器回收蒸汽份额及管道效率 ···……712
附录C(标准的附录)火力发电厂热平衡数据计算汇总表 ·································……713
附录1)(标准的附录)全厂平衡期供电煤耗、供热煤耗、燃料利用率测算表 ··········…·716
附录E(提示的附录)热平衡方框图 ················································,········…… 717
71洲〕
DL理 606.3- 1996
前 言
本标准是根据电力工业部1995年电力行业标准计划项目(第二批)(技综 [1995]44
号文)的安排,由东北电力集团公司制定的。能量平衡是火力发电厂节能工作的一项基础工
作。火力发电厂能量平衡是考核火力发电厂能源利用水平的重要方法之一。
本标准是根据有关国家标准,并吸收火力发电厂在能量平衡工作中的经验和节能的科研
成果而制定的。
根据火力发电厂生产的特点、生产过程和主要能耗,将火力发电厂能量平衡导则分为五
个部分,即:
DL汀606.1 《火力发电厂能量平衡导则总则》
DL/T606.2 火《力发电厂燃料平衡导则》
DL/1606.3 火《力发电厂热平衡导则》
DL/T606.4 《火力发电厂电能平衡导则》
DL汀606.5 火《力发电厂水平衡导则》
在编排上有总则,但还尽可能地保持四种能量平衡各自的独立性,便于应用。本导则是
第三部分D1_/r606.3 《火力发电厂热平衡导则》。
本导则附录A--D都是标准的附录,附录E是提示的附录。
本导则由中华人民共和国电力工业部提出。
本导则由电力工业部标准化领导小组归口。
本导则起草单位:电力工业部东北电力集团公司。
本导则主要起草人:张登敏、王