- 1、本文档共8页,可阅读全部内容。
- 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
PE电缆(国外英文资料)
PE电缆(国外英文资料)
Ultra low frequency measurement of XLPE/PE cable Tan
The Measurement of Tan of XLPE/PE Cables at Hz 8 Very 0.1
Low Frequency
Harbin Electric Power Bureau (Harbin 150001): Sui Wenbo Sun Xianzeng Wang Zuojun
Abstract
Introduces the basic principle and measurement techniques of 0.1Hz ultra low frequency voltage test, which is a new method for field test of XLPE/PE cable. It can measure the cable Tan 8 overall defect sensitive test of cable insulation. The XLPE cable Tan field measurement results are given.
Preface
DC voltage test of XLPE/PE power cable will not easily produce space charge neutralization, not sensitive to detect insulation defects existing in the cable may also cause further damage to the good insulation. DC voltage test is not applicable to XLPE/PE cable has become conclusive; voltage test due to large capacity power supply and test equipment, field test is difficult to achieve.
0.1Hz ultra low frequency voltage test capacity is small, the theory is only the power frequency voltage of 1/500, so the equipment is light, portable, without space charge in XLPE/PE cable insulation, is currently the new XLPE/PE cable more effective test method.
Pressure test is mainly used to detect insulation problem of local obvious flaws and serious global. In order to evaluate the insulation condition of XLPE/PE cable better, in addition to withstand test, but also for other non destructive test, Tan measurement is one of the major projects.
Tan 8 1 0.1Hz frequency measurement technology
1.1 measuring principle
The frequency of the voltage measurement using tan delta QS-1 bridge, using digital automatic balance bridge, the real and imaginary parts of separation, digital sampling waveform analysis method and zero crossing comparison of digital measurement technology.
At the frequency of 0.1Hz, the bridge method is no longer applicable. The field test signal to high frequency interference, the real and imaginary separation method and zero crossing comparison
您可能关注的文档
- DNS常识及故障排除(国外英文资料).doc
- doskey(国外英文资料).doc
- DOS下NET命令的详细使用(国外英文资料).doc
- DOS大全(国外英文资料).doc
- dsfdsfd(国外英文资料).doc
- DVCpro50(国外英文资料).doc
- DXP2004下Miscellaneous Devices.Intlib元件库中常用元件有(国外英文资料).doc
- DXP元件库(国外英文资料).doc
- DXP库(国外英文资料).doc
- D1压力管道考试模拟题1(国外英文资料).doc
- 2024年证券分析与咨询服务项目投资申请报告代可行性研究报告.docx
- 2024年铬酸酐项目资金申请报告代可行性研究报告.docx
- 2024年清洁胶项目资金申请报告代可行性研究报告.docx
- 2024年肉松饼项目投资申请报告代可行性研究报告.docx
- 2024年陆上泵项目资金需求报告代可行性研究报告.docx
- 2024年未硫化复合橡胶及其制品项目资金需求报告代可行性研究报告.docx
- 2024年精密温控节能设备项目资金筹措计划书代可行性研究报告.docx
- 2024年汽车覆盖件模具项目资金筹措计划书代可行性研究报告.docx
- 宋词行书钢笔字帖.pdf
- 我的暑假生活作文三年级300字10篇.pdf
文档评论(0)