PID调整(国外英文资料).doc

  1. 1、本文档共15页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
PID调整(国外英文资料)

PID调整(国外英文资料) Set PID parameters in the field of training materials 1. the scope of PID regulator. PID control is a traditional control method, it is suitable for temperature, pressure, flow and level of almost all the scene, the scene is different, the PID parameter should be set, as long as the parameters are properly can achieve very good effect. Can reach 0.1%, even higher control requirements. Analysis of significance and function index of the 2. PID parameters P, I, D:y=yP+yi+, YD Set the 2.1. P parameter Name: the proportion with parameters, unit (%). The proportion of role definition: size and error of proportional control output is proportional to the size of the error, when accounted for the range of percentage reached P value, the output ratio of =100% function, which is defined as the ratio of P with parameters. That is Yp= x 100% = x 100% = Kp Err (1)? (of which: yP=KP?, Delta Delta =SP-PV, 0-100%) KP=1/ (FS?) Can also be understood as, when the error reaches the range multiplied by P (%), the proportion of output effect reached 100%. For example: range for the temperature control system of 0-1300 DEG C, when P is set to 10%, FS multiplied by P is equal to 130 DEG C, when the error reaches 130 DEG C, the proportion of output function is equal to 100%, the error changes every 1 DEG C, the proportion of output change 0.79%, if need to increase the proportion of the role of regulating ability, need to the P parameter is set smaller, or the smaller the range setting. How much can be calculated according to the method. The P= output value opened /FS 100%? The P parameter is smaller proportion, the dynamic response is quick, the stronger the ability to eliminate the error. But the actual system is inertia, control output changes, the actual PV value changes also need to wait for a period of time will slowly change. Because the actual system is inertia, the effect of the ratio should not be too strong, too strong proportional action will cause system instabil

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档