安全技术数据(国外英文资料).doc

  1. 1、本文档共24页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
安全技术数据(国外英文资料)

安全技术数据(国外英文资料) The minimum illumination should not be less than 0.5lx. Emergency lighting and light evacuation signs can be used as reserve power for batteries, and the continuous power supply time shall not be less than 20 min; buildings with a height exceeding l00m shall not be less than 30 min in continuous power supply time. In case of fire, when the normal lighting power is cut off, it should be automatically switched to emergency power supply in 5S. 12. building fire extinguishers, scope of application, classification of dangerous places Water type, foam, ammonium phosphate dry powder and halon type fire extinguisher should be selected for fighting a fire. Fire extinguishing powder, foam, halogenated alkane and carbon dioxide fire extinguisher should be selected for fighting B fire. Chemical foam fire extinguisher shall not be used for extinguishing polar solvent B fire. Fire extinguishing powder, halogenated alkane, carbon dioxide and dry powder fire extinguisher should be selected for fighting C fire. For extinguishing A, B, C and live fire, ammonium phosphate dry powder and halon fire extinguisher should be selected. Fire fighting equipment for D fire fighting shall be settled through consultation between the design department and the local public security supervision department. Dangerous places are classified into serious danger grade, middle danger level and light dangerous level 13. portable fire extinguishers should be installed on the hook, bracket or extinguisher box. The top shall be less than 1.50 m from the ground, and the height of the ground from the ground shall not be less than 0.15 M. Influence of initial pressure on the 14. gas explosion limit is relatively complex, in 0.1 to 2 under the pressure of MPa, has little effect on the lower explosion limit, a greater impact on the explosion limit; when more than 2 MPa, the explosion limit decreases, explosion limit becomes large, expanding the scope of explosion. 15. explosion proof of electrical

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档