Water for Fire Fighting in High外文翻译.docVIP

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Water for Fire Fighting in High-rise Buildings HORATIO BOND, SFPE, Chief Engineer National Fire Protection Association NFPA Standards provide guidance on water supplies for stand- pipe or sprinkler systems in high-rise buildings, but fire flow, pressure ranges, and the use of tanks and pumps are matters of engineering. T HE Standard for the Installation of Standpipe and Hose Systems, NFPA No. 14, and the Standard for the Installation of Sprinkler Sys- tems, NFPA No. 13, provide guidance on water supplies for these services. The guidelines of both these standards require engineering judgment to determine what should be best for the situation in an individual building or structure. Here are some personal ideas on this engineering for which I have been asked recently. They cover some of the problems I see and some possible solutions. STANDPIPES The NFPA Committee on Standpipes and Outside Protection has ap- pointed a subcommittee to review the Standard for Standpipes and Hose Systems, NFPA No. 14, and it is quite likely that future requirements will deal more comprehensively with high-rise buildings. HAND HOSE In very tall buildings, it is necessary to divide the water supply for normal building services into zones in much the same way that public water systems are zoned in cities with numerous areas on hills. Hand hose for use by building occupants requires a different pressure range than that required for fire department lines. The regular water supply for sanitary and other uses within the various zones of a tall building also has different NOTE: This paper was presented at the National Fire Protection Association Fall Conference, November 16, 1965, at Los Angeles, California. 159 160 Fire Technology pressure requirements. These affect details of how the water supply piping systems are arranged. FIRE FLOW Fire department water supplies should be estimated for each floor of a high-rise building in much the same way that one estimates the fire de- partment

您可能关注的文档

文档评论(0)

莎士比亚 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档