31000轮机大纲概要1
CONTENT
PART I MOORING TEST 3
1. General 3
2. Main propulsion system 4
3. Main diesel generator set 5
4. Emergency diesel generator set 7
5. Oil fired boiler, exhaust gas boiler and steam system 9
6. Air compressor, air receiver and compressed air system 11
7. F.O. L.O. valve quick close system 13
8. FO LO purifiers 14
9. FO system 15
10. LO system 16
11. Cooling water system 17
12. Oily-water separator bilge system 18
13. Ballast pump ballast system 19
14. Fire pumps fire extinguish system 20
15. Sewage treatment plant system 21
16. Incinerator system 22
17. Domestic water drainage system 22
18. Air. Sounding filling pipes 23
19. Valve remote control system 24
20. Level remote gauging system 24
21. Workshop equipment 24
22. ER lifting installation 25
23. ER ventilation 26
24. Air conditioning system 26
25. Mechanical ventilation 27
26. Provision system 28
27. Cargo hold water sprinkling system 29
28. Dead ship recovery test 29
PART II SEA TRIAL 30
1. Main propulsion system 30
2. Exhaust gas boiler 31
3. FW generator 32
4. Shaft vibration and shaft power measurement (only for first vessel) 32
5. Running test for main diesel generator set 32
6. Vibration and noise measurement 32
7. Dead ship recovery test 32
8. Main engine Starting test (according to Part I, 2.2.2) 33
PART I MOORING TEST
General
Purpose
The purpose of the onboard test is to be confirmed that all machineries in the engine room are installed properly and can be operated satisfactorily in their system.
Safety device and alarms to be tested according to “SCHEDULE OF MOORING TEST SEA TRIAL FOR E/R AUTOMATION SYSTEM ”(-946-04).
Test method
Pressure switch
Testing device is to be fixed to the three way joint which is arranged temporarily or permanently on pipe line for pressure switchThe alarm setting pressure and concerned alarm circuit to be checked with the standard pressure gauge by slowly releasing pass through Y cock. The alarm setting pressure can also be checked by means of ch