PKPM砖混结构抗震及其他计算(Seismic and other calculation of PKPM masonry structure)
PKPM砖混结构抗震及其他计算(Seismic and other calculation of PKPM masonry structure)
Seismic and other calculation of PKPM masonry structure
The program is applicable to the calculation of masonry structure and bottom frame - aseismatic wall masonry structure of any plane under 12 floors. Bottom frame - seismic wall masonry structure layer number of 1 or 2.
1. Seismic checking of masonry structure
(1) calculation process of masonry structure seismic verification
Layer is calculated with the bottom shear method and seismic force, according to the floor stiffness and shear wall lateral stiffness distribution of earthquake to each wall section - guide to calculate floor load and wall body weight calculation wall compressive stress, according to the wall cross section the seismic shear bearing capacity calculation formula of calculation of the shear bearing capacity of the wall section.
(2) calculation contents of masonry structure seismic check calculation
Check each big earthquake shear bearing capacity of the wall, calculation object, including Windows and doors hole, large wall, and every piece of the wall in seismic shear when considering the effects of pressure along the slope stepped cross section bad seismic shear strength. The calculation result is the ratio of resistance to effect.
The shear bearing capacity of the wall section of the doors and Windows is checked, and the total cross-sectional area of the horizontal reinforcement of the wall is calculated when the shear bearing capacity of the wall section is not satisfied.
(3) parameter input
Basement structure built in height (mm) 3 layers: when have the basement or a half basement, input the basement or a half basement to calculate the height of the horizontal seismic force of the ground plane, the height value less than three layer height building. (when the input build-in height greater than zero, when calculating the basal total earthquake force does not calculate below ground level structure of gravity load repre
您可能关注的文档
- 5S管理培训讲座(5S management training lecture).doc
- 5分钟让你认识POLO车--POLO常见的问题(Five minutes to get to know POLO, a common problem with POLO).doc
- 600MW机组加氧处理转换过程(The process of oxygen treatment conversion process for 600MW unit).doc
- 6-1第六章 管道设计(Chapter 6 pipeline design).doc
- 64581_2003年度土建专业模拟试卷2(64581_2003 professional simulation exam 2).doc
- 6502电气集中电路_2(6502 electrical centralized circuit _2).doc
- 6XV1830-0EH10,武汉康厦自动化设备有限公司(6XV1830-0EH10, wuhankang mansion automation equipment co., LTD).doc
- 6万发电机组厂用电分配(Electricity distribution for 60,000 generator sets).doc
- 7000 考验单词 五(The test of the word five).doc
- 66-边缘检测算子及其在火焰图像中的应用(66 - edge detection operator and its application in flame image).doc
- proe螺旋扫描指令教程(Proe spiral scanning instruction tutorial).doc
- Proe重点(Proe key).doc
- PROFIBUS现场总线技术综述(PROFIBUS fieldbus technology overview).doc
- Protel DXP 快捷键一览(Protel DXP shortcut key view).doc
- protel 介绍(Protel is introduced).doc
- PLSQL编程(PLSQL programming).doc
- protel快捷方式(Protel shortcuts).doc
- protel快捷键大全(Protel shortcut keys).doc
- PSCAD 4.4 (电力系统计算机辅助设计)(PSCAD 4.4 (computer aided design of electrical systems)).doc
- prote地线的设计(The design of the prote ground line).doc
文档评论(0)