奥的斯3200故障代码(Otis 3200 failure code)
奥的斯3200故障代码(Otis 3200 failure code)
Otis TOEC 2000.300 VF. 3200
OCSS: key sequence
M-1-2-2-1: event record
M-1-2-2-2: operation mode record
LMCSS: key sequence
M-2-2-2: event record
Clear fault method: to clear a single failure, press SHIFT + ENTER to clear the fault in the display when the ST is displayed
If you know all the fault records, press SHIFT + 5 and then follow the instructions above to confirm
OVF30: key sequence
M-4-2-1: view the current failure
M-4-2-2: view storage failure
M-4-2-3: clear fault record
3100 OTIS2000
LCBII: key sequence
M-1-2-1: view the event record
OVF20: key sequence
M-2-2-1: view all event records that have been switched on for the last time
M-2-2-2: check all previous uncleared failure records for the last connection
Troubleshooting method: key SHIFT + 5, then follow the above reminder to clear
Otis 3200 failure code
Fault source system execution
The code server displays
2000 STM software reset electronic board software running error, causing CPU reset
2001 STM power on reset to reset, or press reset button
2002 STM power fail 5V power supply voltage is less than 2.5v. During system outage, the system stops
In 2005 STM not available certain abnormal conditions were detected by MCSS, and other fault records should be checked. In addition, this record was also recorded in emergency or maintenance conditions
Source location reference
The code server displays
22,100 PSR Big pos slip is too large for a wire rope to move in the same direction as the elevator
2101 PSR Big neg slip and the steel wire rope slip too large for the opposite direction of the elevator
The position of PSR Pos mes FLT PVT is located in the flat zone, but DZ has no input and should check the photoelectric
2103 PSR Inv FLOOR COUNT invalid FLOOR counting, COUNT and the actual shaft FLOOR FLOOR number is inconsistent, or exceed the highest or lowest floors. Generally occur in capsules position is moved, when the power is cut off again after sending the fault
2104 PSR
您可能关注的文档
- 吉祥文字(Auspicious words).doc
- 吊篮脚手架(Basket scaffold).doc
- 吊车驾驶员必知应知常规知识(A crane operator must know the general knowledge).doc
- 吊顶装饰材料的选择(The choice of condole top adornment material).doc
- 吊顶设计-设计方法(Ceiling design - design method).doc
- 名烟名酒价格大曝光(Famous tobacco prices have been exposed).doc
- 后勤实习(Logistics practice).doc
- 后张法简支箱梁预应力施工工艺(The prestress construction technology of the post-tensioned box girder).doc
- 后期混缩入门(Introduction of late mixing).doc
- 后置处理方法(Post processing methods).doc
最近下载
- Roland罗兰乐器JUNO-Gi 带数字录音功能的便携合成器JUNO-Gi Workshop 04 Realtime Control in the JUNO-Gi支持文档.pdf
- 天正变频器TVFS9说明书.pptx VIP
- 人教版小学三年级上册语文期末.docx VIP
- SW7203数据手册_V13926596180高效率双向升降压.pdf VIP
- GB50070-2024-矿山电力设计规范.doc
- 学前教育_农村幼儿园户外游戏活动现状的调查研究.docx VIP
- 国开农村经济管理形考作业1-4试题及答案.pdf
- 嵌入式系统基础与实践基于ARMCortex-M3内核的STM32微控制器习题答案.pdf
- 学前教育_传统文化在幼儿园环境创设中应用现状调查.docx VIP
- 2024-2025学年人教版数学三年级上册期末测试卷.pdf VIP
文档评论(0)