安全使用壁挂炉的方法和注意事项(Methods and precautions for safe use of wall hanging furnace)
安全使用壁挂炉的方法和注意事项(Methods and precautions for safe use of wall hanging furnace)
The domestic gas wall hanging furnace is a combination of water, electricity and gas, which can provide the advanced equipment for the life of hot water and independent heating, which is convenient and not affected by external factors. If the owner can use correctly, not only can increase the use efficiency of the wall hanging furnace, can prolong its service life, the main one is big save energy.
About the water pressure
User before use, first check the boiler water table pointer is within the scope of the regulations, instructions specified in the standard for 1-1.2 mpa water pressure, but in the process of actual use, due to the heating system and there is some air in the boiler, when boiler operation, the system of air from the exhaust valve discharge inside the boiler, the boiler pressure will drop irregular; In winter heating, the water in the heating system expands, the system water pressure rises, and the pressure drops after the water cooling, which is normal. The experiment shows that the water pressure in the wall furnace will not affect the normal use of the wall hanging furnace as long as it is kept between 0.5 and 1.5 bar. Water down in 0.5, may be the cause of living hot water hot and cold or normal boot, such as water pressure is higher than 1.5, pressure in heating system, if more than 3, the boiler safety valve will automatically drain, may cause unnecessary loss, under normal circumstances around one to two months to fill water at a time.
Special reminder: after the system rehydrated, the boilers water supply switch must be turned off. The owner of the long-term business trip should close the water supply valve. It is recommended to add a drainage pipe to the safety valve of the boiler to avoid unnecessary loss when the boiler water pressure is too high.
There is a red light on the boiler
When the boiler starts, if the flame is not detected, it will automatically enter
您可能关注的文档
- 唐代部分婚恋诗(In the tang dynasty, some love poems).doc
- 唐汉建筑风格特点(Tang han architectural style characteristics).doc
- 唐山违章地点(Tangshan violation place).doc
- 唐蕃古道骑行攻略(The tangfan road cycling strategy).doc
- 唐菖蒲[剑兰]切花标准(The standard of cut flowers of tang calamus).doc
- 唐诗三百首及作者(Three hundred tang poems and the author).doc
- 售后抱怨应对话术 .txt(After-sales complaints should be talked about. TXT).doc
- 唯美伤感古诗词(Beautiful sentimental ancient poetry).doc
- 唯美诗句(Only beautiful verse).doc
- 商业地产产品发展概述与浅析(Overview and analysis of the development of commercial real estate products).doc
文档评论(0)