网站大量收购独家精品文档,联系QQ:2885784924

什么是零序电流、什么是剩余电流、零序电流保护(What is the zero sequence current, what is the residual current and zero sequence current protection).doc

什么是零序电流、什么是剩余电流、零序电流保护(What is the zero sequence current, what is the residual current and zero sequence current protection).doc

  1. 1、本文档共8页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
什么是零序电流、什么是剩余电流、零序电流保护(What is the zero sequence current, what is the residual current and zero sequence current protection)

什么是零序电流、什么是剩余电流、零序电流保护(What is the zero sequence current, what is the residual current and zero sequence current protection) What is the zero sequence current, what is the residual current, zero sequence current protection and residual? In order to avoid personal contact between electricity and power distribution lines due to various reasons caused by damaged, fire and other accidents, ensure the thermal stability of equipment and lines, the relevant rules of our country, the construction of electrical design are put forward in the low voltage distribution line to ground fault protection settings. In the national standard GB5005495 low-voltage power distribution design standard article 4.4.10 pointed out the ground fault protection of two kinds of method, zero sequence current protection and residual current protection (also known as the RCD). The basic principle of the two current protection is the same, but the scope of application, installation and other requirements are different. Zero sequence current protection concrete application in the three-phase transmission lines are respectively provided with a current transformer (C.T), or let the three-phase conductor through a sequence of C.T, also can install a sequence C.T in neutral line N, and to detect the current vector phase using these C.T, the zero sequence current Io, IA+ IBIC=IO, when the three-phase load balance on the line completely (no grounding fault, without considering the leakage current circuit and electrical equipment), IO=0; when the line three-phase load imbalance, IO=IN, the zero sequence current unbalance current of IN; when one phase ground fault occurs. Must have a single-phase grounding fault current is Id, the zero sequence current detected at IO=IN+Id, is a vector and three-phase unbalanced current and single-phase grounding current. The specific practices of residual current protection is measured in the three-phase guide line and neutral N are respectively provided with a C.T, or let t

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档