网站大量收购独家精品文档,联系QQ:2885784924

四通阀故障的判断及处理(Fault diagnosis and treatment of four way valve).doc

四通阀故障的判断及处理(Fault diagnosis and treatment of four way valve).doc

  1. 1、本文档共11页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
四通阀故障的判断及处理(Fault diagnosis and treatment of four way valve)

四通阀故障的判断及处理(Fault diagnosis and treatment of four way valve) Taolibuyan xiazichengqi. Orderly and progressive, familiar with the fine si. Thanks to welcome Sir heart broken, lashing people sad. The learning without effort, beginning as young old Kung fu. On high, wed be two birds flying wing to wing. On earth, two trees with branches twined from spring to spring。 Fault diagnosis and treatment of four way valve 1., why will cause electromagnetic four reversing valve does not change? How to check and repair? The reason why the electromagnetic four way reversing valve does not change is: The burning of the electromagnetic coil. Cut off the power supply and use the multimeter R*1 to measure the DC resistance value and the on-off condition of the electromagnetic coil. When the measured DC resistance value is much smaller than the specified value, it shows that the electromagnetic coil has partial short circuit. Should replace the same type of electromagnetic coil, in the replacement, should pay attention to before the coil is inserted into the center of the magnetic core, cant do electricity check, otherwise easy to burn the coil. The vent holes on the piston valve is blocked. The valve piston vent diameter is only 0.3mm., although the hole before the filter, if the refrigeration system is not clean, easily blocked, can not change the cause of failure. For this kind of fault, the following treatment can be carried out as follows: repeatedly switching on, cutting off the circuit of the electromagnetic coil, reversing the reversing valve so as to flush the dirt. If it is still blocked, remove the reversing valve to wash or replace the electromagnetic four way reversing valve. The leaking valve piston bowl. Turn the temperature control knob of the refrigerating air conditioner clockwise until the air conditioner stops working. After 3min, the high and low pressure tend to balance, and the reversing valve is energized again. So repeated several times, if still invalid, can o

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档