网站大量收购独家精品文档,联系QQ:2885784924

变压器的平均负荷功率如何计算(How is the average load power of a transformer calculated).doc

变压器的平均负荷功率如何计算(How is the average load power of a transformer calculated).doc

  1. 1、本文档共16页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
变压器的平均负荷功率如何计算(How is the average load power of a transformer calculated)

变压器的平均负荷功率如何计算(How is the average load power of a transformer calculated) How do you calculate the average load power of a transformer?.txt people never know who inadvertently said goodbye to you, and then you really never see them again. How long is a minute? It depends on whether you are squatting in the toilet or waiting outside the toilet...... How is the average load power of a transformer calculated? [Tags: transformer load, transformer, average, An] (static. Answer: 1 solve popularity: 16 time: 2009-08-23 16:45 Answer: 0% introduction: the average load factor of the load curve is higher, the loss of power to achieve smaller loss than to use smaller transformers; load curve of the average load factor is low, the loss of power to achieve smaller transformers, the greater the loss ratio to use. By multiplying the average load factor of the load curve by a multiple greater than 1, it is usually desirable to use 1-1.3 as the load factor for optimum efficiency, and then calculate the loss ratio that the transformer should have at the rate of B = (1/R) 1/2. Key words: Transformer 1. Calculation formula of transformer loss (1) active loss: Delta P = P0 + KT, beta 2PK------- (1) (2) reactive loss: Delta Q = Q0 + KT, beta 2QK------- (2) (3) comprehensive power loss: Delta PZ = Delta P + KQ, Delta Q---- (3) Q0 = I0%SN, QK = UK%SN Type: Q0 - no load reactive power loss (kvar) P0 - no-load loss (kW) PK - rated load loss (kW) SN - rated capacity of transformer (kVA) I0% - percentage of no-load current of transformer. UK% - percentage of short-circuit voltage Average load factor KT - load fluctuation loss factor QK - rated load magnetic flux leakage power (kvar) KQ - reactive economic equivalent (kW / kvar) Selection conditions of parameters in upper calculation: (1) take KT = 1.05; (2) when the minimum load is taken from the 6kV to 10kV step-down transformer of the urban power grid and the industrial enterprise power grid, the reactive power equivalent KQ = 0.1kW / kvar; (

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档