DIY数字电桥说明 - EEVblog.DOC

  1. 1、本文档共46页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
DIY数字电桥说明 - EEVblog

DIY digital bridge Description Xu Jianwei Putian TenthI. Overview: Crystal radio play, most of the components needed DIY, it is necessary to know the parameters element. Since no elements of DIY nominal technical parameters. For example, the devices need to know the characteristics of the reactance of the resonance means, detection means, an antenna, an earphone, transformers and the like. Wherein Q, frequency parameters can be used to solve the problem, the parameter Q for the low frequency is difficult to measure. To solve this problem, we believe that the LCR digital bridge capable. 稤esign goals: 1, it is possible to accurately measure the reactor L, C, R, accuracy of better than 0.5%, if the manual shift by calibration, accuracy of better than 0.3% 2, drawing easy, Jian Jie circuit, easy to make, cost should be properly controlled. So that it has more value and amateur DIY research value, and to learn details LCR bridge, through the design principle, DIY. The basic characteristics of the Ben LCR table AD converter Word Count: about 1000 words, using the oversampling technique, the effective resolution of approximately 2000 words Measurement method: quasi-bridge assay, the measurement principle is similar to the proportion of resistance measurement. The main measuring range: 0.5 to 1 megohm Europe, precision 0.5% (theoretical), comparing the measured impedance, no more than 0.3% Effective measuring range: 2 to 10 milliohms megohm, minimum resolution 1 milli-ohm Series residual error: 2 milliohms, when this error is not negligible low resistance measurements Parallel residual error: 50M Europe, this high-impedance measurement error is not negligible Q error:?.003 (Q 0.5), Q / 300 (Q 2, the relative error, simple algorithm), the other by about 0.5% Estimation, D error:?.003 (D 0.5), D / 300 (D 2, the relative error, simple algorithm), the other by about 0.5% Estimation, Note: Q = 1 / D Test signal amplitude: peak 200mV (100Hz), 180mV (1kHz), 140mV (7.

文档评论(0)

youbika + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档