2陈青来06g101-6解疑 - 学习资料共享 栋梁之财(2 Chen Qing 06g101-6 - learning disambiguation data sharing the pillars of the property).doc
- 1、本文档共11页,可阅读全部内容。
- 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
2陈青来06g101-6解疑 - 学习资料共享 栋梁之财(2 Chen Qing 06g101-6 - learning disambiguation data sharing the pillars of the property)
Otherwise its too thick.
4. Can the bottom reinforcement of the seismic frame beam overlap? Where does it overlap?
Answer: the bottom ribs of the seismic frame beam can be lapped, so long as it is not in the middle part of the lower part of the beam.
5. How many times should the total length of the two hooked hooks be d?
Answer: stirrup two bending hook, if it is 135 degrees, seismic situation is 11.9d, not seismic when 6.9d.
6, when the dark column is too long, the horizontal distribution of the shear wall should be extended to the end of the hidden column or to consider the overlap with the blind column stirrups?
Answer: no matter how long the dark column is, the dark columns belong to the wall. It is a part of the wall, not the support of the wall, so it should be extended to the end of the dark column. It can not be lapped.
7, brick structure, structure column and ring beam, which is the seat?
Answer: in the masonry structure, two belong to the whole building strengthening component, column beam is certainly support, however, when the actual effect of the main load-bearing components in the brick concrete structure wall is not structural column, so this relationship not so obvious frame structure.
8, the non frame beam L bottom reinforcement anchorage length is 12D, or press 03G101-1 thirty-third page third points: in any case, the anchor length shall not be less than 250mm?
Answer: this can take the 12D directly, and the lower steel bar of L belongs to the compression zone, which is different from the frame beam. 250mm refers to the minimum anchor length of the tensile steel bar.
9. What is the length of the overlap between the distributing ribs of the plate and the negative tendons in the other direction?
Answer: the function of the distribution reinforcement is to make the main reinforcement banding into the net, and the main reinforcement pos