Trends in the design of suitability test for high performance liquid chromatography systems
Classification: liquid knowledge
Effective liquid chromatography (HPLC) is a qualitative and quantitative chromatographic analysis method commonly used in drug analysis. It has strong specificity, relatively high detection sensitivity and good quantization function. The 2005 edition of Pharmacopoeia method using HPLC China varieties, applicability test design of chromatographic system has changed: index more meticulous and thoughtful, more pragmatic, applicability test of chromatographic system with solution preparation methods are also diversified, reflect some tendency.
The suitability of the 1. chromatographic system test design is more matched with the experimental purpose
The precise degree of suitability of the system depends on the purpose of the experiment. First of all, we should consider what kind of experiment the chromatographic system is used and design the suitability test of the system according to the experimental purpose. If a HPLC method is only used for qualitative identification, the test of the applicability of the chromatographic system can be relatively simple and relaxed, as long as it can ensure that the measured component peak and other peaks have a certain degree of separation, with suitable peak time can achieve the purpose of the experiment.
If used for quantitative analysis (such as determination), in addition to ensure that the measured component peaks with suitable peak time, it also needs to check whether the system can ensure that the measured peak components completely separated from other peaks, the degree of separation in general should be more than 1.5, should also be tested into repetitive peak peak the area is good, the control of peak area solution injection needle 5 relative standard deviation should be no greater than 2%, the measured peak peak components should also be symmetrical, in order to ensure th
您可能关注的文档
- 地震前兆(earthquake precursor).doc
- 美丽女人的华彩霓裳(Colorful neon beautiful woman).doc
- 地震征兆(Earthquake omen).doc
- 美剧常见词(Common words in American drama).doc
- 美发话术(Hairdressing talk).doc
- 美国ni仪器公司产品ni labview 2014 v14.0.1(美国镍仪器公司产品NI LabVIEW 2014 v14.0.1).doc
- 美国人的赚钱高招(American money making ideas).doc
- 美国人造鸡蛋(American made eggs).doc
- 美国俚语(american slang).doc
- 美国特享腺体元素资料(Information on gland elements in the United States).doc
文档评论(0)