药物分析(pharmaceutical analysis).doc

  1. 1、本文档共9页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
药物分析(pharmaceutical analysis)

药物分析(pharmaceutical analysis) Trends in the design of suitability test for high performance liquid chromatography systems Classification: liquid knowledge Effective liquid chromatography (HPLC) is a qualitative and quantitative chromatographic analysis method commonly used in drug analysis. It has strong specificity, relatively high detection sensitivity and good quantization function. The 2005 edition of Pharmacopoeia method using HPLC China varieties, applicability test design of chromatographic system has changed: index more meticulous and thoughtful, more pragmatic, applicability test of chromatographic system with solution preparation methods are also diversified, reflect some tendency. The suitability of the 1. chromatographic system test design is more matched with the experimental purpose The precise degree of suitability of the system depends on the purpose of the experiment. First of all, we should consider what kind of experiment the chromatographic system is used and design the suitability test of the system according to the experimental purpose. If a HPLC method is only used for qualitative identification, the test of the applicability of the chromatographic system can be relatively simple and relaxed, as long as it can ensure that the measured component peak and other peaks have a certain degree of separation, with suitable peak time can achieve the purpose of the experiment. If used for quantitative analysis (such as determination), in addition to ensure that the measured component peaks with suitable peak time, it also needs to check whether the system can ensure that the measured peak components completely separated from other peaks, the degree of separation in general should be more than 1.5, should also be tested into repetitive peak peak the area is good, the control of peak area solution injection needle 5 relative standard deviation should be no greater than 2%, the measured peak peak components should also be symmetrical, in order to ensure th

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档