综合布线系统要点(Main points of generic cabling system)

综合布线系统要点(Main points of generic cabling system) The design of the bridge is reasonable, so as to ensure the proper bending radius of the cable. When the upper and lower sides are around the other line grooves, the slope of the turn should be gentle, and the key point is that the cable at both ends will sag. After the force is applied, the cover plate can also be laid on the premise that the cable is not damaged. On line process is mainly control the tension, the tape reel cable, at least two suggestions to arrange for a worker to scroll in Guyed pole homemade, line end workers first pulled out a part of the cable from the scroll box for the pipeline in the pre, the other end of pre extraction. Pull out of the line can not be too much, to avoid entanglement with a plurality of lines on the ground around. Stay after the operation, both sides of the cable for redundancy to collate and protect the disk line along the direction of rotation of the original coil diameter, not too small, if possible with waste thread fixed on the tray, ceiling or cartons, do mark, to remind other personnel do not move, do not step on. In the finishing, binding, cable placement, redundant cable should not be too long, do not let the cable stress superposition, coil with consolidation, fixed rope not looking too tight. Throughout the construction process, timely notification of the process, the person in charge of various types of work to communicate, to identify problems immediately notify Party A, in other follow-up work before the start of the timely completion of the task of this type of work. If the installation is unshielded twisted pair, the docking site is not high enough to be earthed at the main slot connected to the cabinet. The specification of the slot is to confirm that the cross section of the slot remains 40% of the surplus to be expanded, and the cross section area of the over 5 types of twisted pair is 0.3 square centimeters. When installing the slot, attention should be pai

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档