春兰空调故障维修代码表(Code for fault maintenance of Chunlan air conditioner)
春兰空调故障维修代码表(Code for fault maintenance of Chunlan air conditioner)
Code for fault maintenance of Chunlan air conditioner
--------------------------------------------------------------------------------
Chunlan KFR-40, 50, 70, 100, 140LW/BdS
Reasons of fault E1 fault display room inside and outside communication (voltage between GND and CMM swing around 6-7V) E2 compressor current E3 power supply voltage abnormal E4 refrigeration system high pressure protection, RT5 sensor abnormal E5 outdoor low temperature cold ring protection E6 protection (refrigeration state) E7RTI, RT2, RT3, RT2 abnormal temperature sensor open, E8RTI RT2, RT3 temperature sensor short
Chunlan FR-180 and 260/S pipe mill
Show the reason code E0 system fault voltage protection E1 two anti freeze protection E2 indoor temperature sensor open or short tube E3 indoor temperature sensor open circuit or short circuit E4 outdoor pipe temperature sensor open circuit or short circuit fault E6 E5 communication power supply protection E7 overcurrent protection E8 unloading protection E9 low voltage protection
Chunlan RF-28W/AS10 air conditioning unit fault code
Display power reasons of overvoltage and undervoltage fault lights three-phase power supply normal power over-voltage, flashing lamp power supply voltage is too low or too high (187-245V) abnormal defrost, lack of light air conditioning normal defrosting defrosting, phase light flash three-phase power phase (check signal line H and LP delay) overload, light air conditioning is three minutes delay delay, overload lights flash
Heat protection K disconnect from voltage controller (check signal line B)
Indoor signal wire terminal is defined as follows: A - B - power line voltage control and thermal protection input control line (weak ground), C - compressor output control line (weak ground), D outdoor pipe temperature sensor input connections (weak ground), E outdoor machine output control line (weak ground), F outdoor machine output control line (weak gr
您可能关注的文档
- 对入世后我国烟叶生产的几点思考(Some thoughts on tobacco production in China after joining WTO).doc
- 富康车故障的排除(Trouble removal of Fukang car).doc
- 对和平型人格的建议(Advice on a peaceful personality).doc
- 对国外教育评价模式的价值取向评析(Analysis of the value orientation of foreign educational evaluation model).doc
- 对堵车的一点看法(A view of traffic jam).doc
- 对外交决策和中美关系的几点思考(Reflections on foreign policy decisions and Sino US relations).doc
- 对学生干部的认识(Understanding of student leaders).doc
- 对山峰厂营运能力分析(Operation capacity analysis of peak plant).doc
- 对我国适用公司法人格否认法理的质疑(Query on the legal principle of disregard of corporate personality in China).doc
- 对微博博营销,电管理子商务,新营销的新思考(New thoughts on micro-blog Bo marketing, electric tube business, new marketing).doc
文档评论(0)