格力空调制热时常出现外风机停机现象(GREE air conditioning system often appears outside fan stop phenomenon)
格力空调制热时常出现外风机停机现象(GREE air conditioning system often appears outside fan stop phenomenon)
GREE air conditioning heating often fan stop phenomenon, preventing indoor temperature protection
GREE air conditioning heating often fan stop phenomenon, preventing indoor temperature protection
Because some machines often appear fan stopping phenomenon in heating (anti indoor temperature protection). The investigation by the indoor machine temperature turns small, still have customer service parts warehouse controller tube temperature sensing packet is 5 K Omega, the barber to notice as follows:
1, the GREE 2000 series (including D machine), cloud, hummingbird controller. If the motherboard X117 is not directly welding temperature sensing needle board in the PCB package, the tube temperature temperature is 10K; otherwise, need to change according to the following method: remove the X117 needle, resistance to change R123 metal film resistor 8.4K or 8.4K , sheet resistance to indoor the tube temperature sensing packet (GREE 2000, hummingbird TY.13.02.66 encoding: FY TY.13.02.76 encoding: is directly welded on the PCB board.
2, GREE 2000 inverter controller. If the motherboard X105 is not directly welding temperature sensing needle board in the PCB package, the tube temperature temperature is 10K; otherwise, need to change according to the following method: remove the X105 needle, resistance to change R123 metal film resistor 8.1K , the indoor temperature control temperature (TY.13.02.66 encoding: is directly welded on the PCB board.
3, honey controller. If the motherboard X105 is not directly welding temperature sensing needle board in the PCB package, the tube temperature temperature is 10K; otherwise, need to change according to the following method: remove the X105 needle, put the R123 into the 8.4K metal film resistor , the tube temperature sensing packet TY.13.02.66A (encoding: is directly wel
您可能关注的文档
- 导游考试名词解释(Explanation of tour guide examination term).doc
- 对折现率性质的界定(Definition of the nature of discount rate).doc
- 导热油在粗苯加氢精制工艺中的应用(Application of heat conducting oil in crude benzol hydrofining process).doc
- 对社会舆论监督必要性的认识(Understanding of the necessity of supervision by public opinion).doc
- 对电梯和消防联动的一些认识(Some understanding of elevator and fire linkage).doc
- 导致电脑网速过慢的原因详解(Causes the computer network speed to be too slow to explain).doc
- 导致网速变慢的8种情况(8 cases that lead to slower network speed).doc
- 导致企业决策失误的五企业培训个因素(Five enterprise training factors leading to enterprise decision making errors).doc
- 导出图层设置 revit(Export layer settings Revit).doc
- 对当的认识(Knowledge of the future).doc
文档评论(0)