analysis of the structural system of environmental protection energy-saving building construction technology _ cl(结构体系的分析_ cl环保节能建筑施工技术).doc
- 1、本文档共9页,可阅读全部内容。
- 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
analysis of the structural system of environmental protection energy-saving building construction technology _ cl(结构体系的分析_ cl环保节能建筑施工技术)
Analysis of the structural system of environmental protection energy-saving building construction technology _ CL
Paper to write network: Paper Keywords: CL system of environmental protection energy-saving building design and construction
Abstract: The example describes the CL architecture construction technology and the technical superiority.
1 Project Overview
The total area of ??about a plot, of which l0 million for the CL architecture, this structure integrates the new structure, new materials, new processes, new technology, and Hebei Province to promote energy conservation, residential green building pilot projects.
2 CL structure system design and application
(1) system design: CL (Composite light-weight) is a new system architecture, CL is a CL structure wall (CL wall-panel) and physical silicon wall, floor or cast integral assembly floor after pouring from the edge of the spatial structure of connected components, mechanical performance is a wall structure. CL CL wall of the main wall by the force component on both sides of cold drawn low carbon steel wire welded CL Smooth mesh (CL netflake) and three-dimensional oblique abdominal wire (galvanized low carbon steel wire) welded into the space frame, sandwiching the formation of polystyrene plates CL grid plate (CLnet-frame panel), after the pouring of concrete composition on both sides inside and outside the CL wall. CL wall of 180 mm, the middle of CL Core (CL corepanel) a polystyrene board is 50 mm, density, thickness of concrete inside 90 mm, thickness of the outer concrete 40 mm, both inner and outer steel wire mesh spacing of 50 mm, outside of 4 mm cold drawn low carbon steel wire mesh, 3 mm medial to low-carbon steel wire cold-drawn films, abdominal galvanized low carbon steel wire of 3mm.
Core CL Class Ⅱ insulation with the use of molded polystyrene foam board, performance indicators: the performance of the density range; flame retardant (zR-type) oxygen indexgt; = 30%, the rest sh
您可能关注的文档
- analysis of the passion is teaching chinese language and literature teacher at the quality of essential(激情是分析教学语文教师的质量至关重要).doc
- analysis of the perfect system for librarians to promote harmonious development of the library(分析图书馆员的完美系统,促进图书馆和谐发展).doc
- analysis of the pdca method in the municipal engineering project management application(pdca方法分析市政工程项目管理应用程序).doc
- analysis of the patriotic education of college students(分析大学生的爱国主义教育).doc
- analysis of the people of lanzhou investment analysis and development(分析兰州人民的投资分析和发展).doc
- analysis of the personal characteristics of the perpetrator footprint analysis(分析罪犯的个人特征的足迹分析).doc
- analysis of the personal income tax to the town of income and consumption empirical analysis(分析了个人所得税的收入和消费的实证分析).doc
- analysis of the pharmacological effects of solidago(分析一枝黄花的药理作用).doc
- analysis of the petrochemical plant process piping system pressure test analysis(石油化工装置工艺管道系统压力试验的分析分析).doc
- analysis of the phenology theory and practice of architecture(物候学理论和实践的分析架构).doc
文档评论(0)