减压器说明书(英)
XJA1 Auto Voltage Reducing Starter
User Manual
Standard number:GB14048.4-2003Chang an Group Co. Ltd.
Ⅰ Outline
1. Applied as less frequent reduced-voltage starting for three-phase squirrel-cage induction motor of rated voltages and capacity up to and including 380V and 320kw, the starter minimizes the influence to the transmission network.
2. Working indoors and under following conditions:
Altitude ≤ 3200w
Temperature within -5℃and 40℃, with a 35℃average
Relative humidity under 85%
Amplitude≤0.5mm, frequency≤600/m
≤5°angle from the vertical
Neither in the environment with metal-corrosive or insulation-disturbing gas nor in the air with inductive or explosive dust.
Protection degree IP20
3. The model symbol is illustrated as follows:
X J A1 □
Ⅱ Starting Performance
4. To start an electric motor with XJA1, the starting current is 3-4 times over the rated and it should be done within 15 seconds. When using it twice in a roll, wait until it cools down to the room temperature, for frequent operation disturbs its performance.
Ⅲ Structure
5. XJA1 is designed as a central box structure, consisting mainly of an autotransformer, an AC contactor, a thermal relay, an intermediate relay, a time relay. Those up to 75kw apply automatic control system. Those 85kw and above apply two modes with an auto-man switch and an adjustable time relay, and starting time can be adjusted at between 5 and 15 seconds. There are two models of tapped coils, one with 65% rated voltage as the original default and an 80% one when necessary.
Ⅳ Technical Content
6. See Table 1 for technical content.
Model Rating
(kW) Max operating current Ie(A) Auto-transformer rating(KW) ratio(K) Relay setting current reference value(A) 7. The table above is only for reference. The setting value should be adjusted to the actual rating of the motor used. Change the thermal relay when necessary.
(1)set at Ie value for up to and 75kW
(2)set at XIe value for 80kW and abo
您可能关注的文档
- LinuxShell脚本,Oracle.doc
- linux vsftpd服务.doc
- 好S3C2440的中断控制器.doc
- 2014版 译林牛津8B Unit2综合测试题 及答案.doc
- ch1ch2ch3讲义.doc
- CCNP实验MPLS_VPN_new.doc
- Windows虚拟内存管理.docx
- OSPF的特殊区域讲解.doc
- 计基课本课后习题.doc
- 易码单片机 P15中文资料.doc
- 江苏省张家港第二中学2025届高考历史三模试卷含解析.doc
- 2025届江苏省扬州名校高三下学期联合考试生物试题含解析.doc
- 海南华侨中学2025届高考临考冲刺历史试卷含解析.doc
- 重庆市江津区永兴初级中学2025届高考历史考前最后一卷预测卷含解析.doc
- 河南省郑州市第七中学2025届高考考前提分历史仿真卷含解析.doc
- 2025届新疆维吾尔自治区生产建设兵团第二中学高考历史全真模拟密押卷含解析.doc
- 福建省龙岩市一级达标学校2025届高考历史押题试卷含解析.doc
- 广东省广州市增城中学2025届高三下学期第五次调研考试历史试题含解析.doc
- 2025届江苏省灌南高级中学高三下学期联合考试历史试题含解析.doc
- 山东省济宁市重点中学2025届高考考前模拟生物试题含解析.doc
文档评论(0)