4台以上并机方案(英文)

For upto 4 units in parallel , this is exactly like say 2 or 3 units in parallel. Say for 4 x 480 KVA configurations - you will need: DP3480E - 4 units Parallel Card for DP3480E - 4 units (1 sitting inside each unit) MCCB Box - 4 units (1 for each UPS) Service Bypass for 4 x DP3480E - 1 unit (specify redundant n+1 or full power i.e. whether load is 480 x 3 KVA or 480 x 4 KVA) Electronic Static Switch - Built in every unit (no need to add deperately) The diagram will be exactly same as for 2 or 3 x DP3480E or 4 x DP3480E. For more than 4 units, we shall need an External Static Switch - so the things will change to:Say for 6 x 480 KVA DP3480E - 6 units Parallel Card for DP3480E - 6 units (1 sitting inside each unit) MCCB Box - 6 units (1 for each UPS) Service Bypass for 6 x DP3480E - 1 unit (specify redundant n+1 or full power i.e. whether load is 5 x 480 KVA only or 6 x 480 KVA - in example below it is 5 x 480 KVA) Electronic Static Switch - External to be capable of handling full power of load (say 6 x 480 KVA for full power or 5 x 480 KVA for redundancy - in example below it is 5 x 480) This diagram will look something like: In this option, the load is 5 x 480kVA = 2,400 kVA, which can be handled by 5 UPS modules. The 6th module is parallel operating and sharing the load in redundant operation. Normally on full load operation, each of the 6 UPS active modules is running at 5/6th i.e. about 85% load only. An external Static Switch is used to handle any overloads outside the rating of Online Operation or failure of more than 1 module. The Static Switch is rated for 5 x 480 KVA load. A single line drawing is attached below to give an impression of the arrangement. PARALLEL OPERATION OF DP300E Sambhaji Wagh APC, Singapore In DP300E systems parallel operation works as follows We can connect upto nine units of same capacity in parallel to achieve redundancy or increased load capacity in UPS system. The configuration will look as follows We have supplied this kind o

文档评论(0)

xcs88858 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8130065136000003

1亿VIP精品文档

相关文档