LEED美国绿色建筑认证考试官方复习材料 EQ

Learning to LEED: Day 2 Indoor Environmental Quality Quiz 1. Number of Prerequisites in the Indoor Environmental Quality category: Number of Credits in the Indoor Environmental Quality category: Number of Points in the Indoor Environmental Quality category: 2. Within the Indoor Environmental Quality category, which of the following credits can only be submitted during the construction phase of the project? (Choose two.) EQc1, Outdoor Air Delivery Monitoring EQc2, Increased Ventilation EQc3, Construction IAQ Management Plan EQc4, Low-Emitting Materials EQc5, Indoor Chemical Pollutant Source Control EQc6, Controllability of Systems 3. Match the following statements with their respective points: EQc8.1, Daylighting Views, Daylight 75% of Spaces EQc8.2, Daylighting Views, Views for 90% of Spaces If the percentage of floor area in a private office experiencing [daylight or direct line of sight] is 75% or greater, the entire square footage of the room may count toward the requirement for the point Draw a horizontal line at 42” In ALL cases, only the square footage meeting the minimum requirements of the point may be counted toward its achievement Take measurements on a 10-foot grid for all occupied spaces 4. In order to achieve EQc3.1, Construction IAQ Management Plan, During Construction, permanently installed air handlers during the construction and pre-occupancy phases must have a filtration media of at least MERV . In order to achieve EQc5, Indoor Chemical Pollutant Source Control, air filtration media installed prior to occupancy must provide at least MERV . 5. Match the following requirements with their respective point: MRc3.1, Construction IAQ Management Plan, During Construction MRc3.2, Construction IAQ Management Plan, Before Occupancy Perform a building flush-out with 14,000 cu.ft. of outdoor air per sq.ft. of floor area Protect stored on-site or installed absorptive materials from moisture damage Meet or exceed the Control Measure of

文档评论(0)

pangzilva + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档