网站大量收购独家精品文档,联系QQ:2885784924

kv电流互感器变比的选择(Selection of ratio of kV current transformer).docVIP

kv电流互感器变比的选择(Selection of ratio of kV current transformer).doc

  1. 1、本文档共21页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
kv电流互感器变比的选择(Selection of ratio of kV current transformer).doc

10kv电流互感器变比的选择(Selection of ratio of 10kV current transformer) Selection of ratio of 10kV current transformer The design process in the 10kV distribution in the ratio of 10kV current transformer selection is very important, if the choice is undeserved, it is likely to cause the relay protection function can not be achieved, not through the test of dynamic stability problems, sufficient attention should be paid to the design personnel. 10kV current transformers can be divided into two kinds according to their use, one for relay protection and the other for measurement. They are located in the distribution line, metering, outgoing line and liaison cabinet. In the design practice, the author found that in the distribution transformer substation design, the choice of the current transformer ratio is too small. For example, the author has found that: the station of transformer in a 630kVA (a 10kV rated current is 36.4A) in a power supply loop, the distribution of the outgoing cabinet within the current transformer ratio is only 50/5 (using the GL type DC current relay, this will cause the current operation), relay without setting a series of law the problem. The ratio of 10kV with the selection of current transformer relay protection, at least according to the following conditions: one is to choose a side for calculating the current current transformer rated primary current ratio; according to the requirements of relay protection; three for the calculation of current transformer secondary current is less than MJS times the number of current transformer according to the four times of MB1 saturation; thermal stability; dynamic stability for five. For 10kV current transformer for measurement, because it is used as a measurement of normal working conditions, so the second and third requirements; here in common distribution transformer as an example, shows the influence of above factors on the selection of 10kV current transformer, and find out the main factors influencing th