钢渣微粉改性碳纤维混凝土的电热效应及温升试验研究-水工结构工程专业论文
Abs
Abstract
万方数据
万方数据
Abstract
When short carbon fiber was mixed into the concrete, it could make the concrete have favorable conductivity. Under the effect of outer electric field, carbon fiber reinforced concrete (CFRC) could produce electric heating effect, which could be applied to indoor heating and snow and ice melt of the road. But because of the high conversion cost of CFRC, and the complexity of the electrodes and wires in its construction process, its promotion and application was hindered. Considered these two problems, this paper wished to make a contribution on the promotion and application of CFRC through reducing the mixture of carbon fiber to decrease conversion cost and improving the arrangement of electrode to simplify construction.
The main content of this paper is as follows:
The influences have been researched on the coupling of different mix of carbon fiber and steel slag powder to the volume resistivity of concrete. The consequence of experiment indicates that steel slag powder was mixed to CFRC, which could reduce the mixture of carbon fiber; When the carbon fiber volume ratio was 0.58% and the content of steel slag powder was 20% by weight of cement, the volume resistivity of CFRC was stable and met the design requirement of Deicing and Snow melting.
The influences have been researched that of different electrode arrangement methods (including both ends electrode and closed electrode, the closed electrode includes square shape and round shape, and electrode material is stainless steel wire), different inner electrode sizes, different input voltages to the electro-thermal effect of concrete slab from mix carbon fiber and steel slag powder. The consequence of experiment indicates that temperature rising rate of the slab of CFRC which the rate of two other placements, and surface temperature distribution was uniform.
Research on the temperature rise test of the concrete slabs , the influence in oven-dried condition and saturated water conditio
您可能关注的文档
- 钢框架-预制混凝土抗侧力墙装配式结构施工和使用阶段竖向受力性能研究-结构工程专业论文.docx
- 钢框架内填Rc剪力墙结构内力计算分析简化模型-结构工程专业论文.docx
- 钢框架体系优化设计研究-结构工程专业论文.docx
- 钢框架加腋节点的力学性能研究-结构工程专业论文.docx
- 钢框架内填钢混凝土组合深梁动力弹塑性分析-防灾减灾工程及防护工程专业论文.docx
- 钢框架半刚性连接的三维非线性有限元分析-结构工程专业论文.docx
- 钢框架半刚性连接的三维非线性有限元研究-结构工程专业论文.docx
- 钢框架变截面柱异型节点抗震性能及含该类节点柱计算长度分析-结构工程专业论文.docx
- 钢框架外伸端板连接节点M-θ关系研究-结构工程专业论文.docx
- 钢框架整体结构在火灾下行为的研究-机械设计与理论专业论文.docx
文档评论(0)